Competitive Cross Reference

Macromatic offers this cross-reference as a service to our customers to assist in the selection of replacement products.  Every effort has been made to insure that these products are electrically and functionally equivalent to the Macromatic products except as noted.   Macromatic cannot be responsible for errors of printing or corrections of data taken from published competitive data.  It is the user's responsibility to insure the suitability of the substitution.

If you have any questions regarding these cross-references, or need to cross reference any product not listed, please contact Macromatic.

* If a part number is not found, select the "Series Name" from the right-hand drop down.

Macromatic Equivalent

Catalog Number: THS-1054D-16R7

May not be exact product—for reference only.

  • TIME DELAY RELAY
  • INTERVAL ON
  • 0.6-60 Min delay adjusted remotely with 1M potentiometer (customer supplied)
  • 12-125V DC
  • 1A NORMALLY OPEN (SOLID STATE)
National Controls Corp (NCC) Product
  • Competitor Part # Q4F-03600-326 | Series: Q4F

    Differences:

    NCC unit has time range of 180-3600 Sec. & input voltage of 12VDC; Macromatic unit has time range of 36-3600 Sec. & input voltage of 12-120VDC

Description Of Function Upon application of input voltage, the output is energized and the time delay (t) begins. At the end of the time delay (t), the output is de-energized. Input voltage must be removed to reset the time delay relay.
Function Chart
Application Information
  • Voltage Tolerance: DC Operation: +10/-15% of nominal.
  • Load (Burden): Maximum of 1 VA for all voltages
  • Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%; Minimum Setting (Adjustable): +0%, -50%; Fixed Time Delay: +2% or 50ms, whichever is greater
  • Repeat Accuracy (Constant Voltage & Temperature): +0.1% or + 0.04 seconds, whichever is greater
  • Reset Time: 50ms
  • Output Contacts: Solid State 1A Continuous, 10A Inrush @ 65o C
  • Life: No predictable failure if used within operating parameters.

    Leakage Current (OFF-State): <10 uA @ 125VDC

    Minimum Load Current: 0mA

    Effective Voltage Drop (ON-State): Maximum 0.69V @ 1A for all voltages

  • Temperature: -28o to 65oC (-18o to 149oF)
  • Approvals:

    c-ur-us.jpg  CE_Logo.gif  
Dimensions - Inches (Millimeters)
Macromatic Distributor Stock Status
  • The THS-1054D-16R7 is not stocked by any Macromatic distributor. Please see below for any product substitutions.

    Contact Macromatic for more information or how to purchase this product.

Contact Macromatic

Fill out this form to have Macromatic contact you about this product.

 

 

©2025 Macromatic Industrial Controls, Inc.

2201 Corporate Drive
Waukesha, WI 53189

800-238-7474 • 262-781-3366

Rep Login | Newsletter Sign Up | Articles | Employment | Privacy Policy | Sitemap
Knowledgebase General | Alternating Relays | Current Sensing Relays | Intrinsically Safe Barrier Relays | Liquid Level Control Relays | Seal Leak Relays | Three-Phase Monitor Relays | Time Delay Relays | Voltage Monitor Relays