ARF Series Duplex

Inner-Door Mounting

Flange-enclosure designed for deadfront door-mounting

Flange-enclosure designed for deadfront door-mounting

Top-Mounted Switch accessible without opening inner door

Top-Mounted Switch accessible without opening inner door

Features
  • For Duplex Control of Two Loads
  • Control Voltages of 12 & 24V AC/DC and 120 & 240V AC
  • Two 10A Output Contact Configurations: SPDT or DPDT Cross-Wired
  • Low Profile Selector Switch to Lock in One Sequence
  • Selector Switch Accessible without Opening Inner Door
  • 2 LEDs Indicate Relay Status
Enclosure Style Flange enclosure designed for deadfront door-mounting
Configuration/
Contact Rating
  • SPDT & DPDT Cross-Wired
  • 10A @ 240V AC/24V DC, 1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.)
Approvals ur.gif   CE_Logo.gif    UL-socket.jpgUL File #E109466
Technical Documentation

Duplex Alternating Relays are used in special applications where the optimization of load usage is required by equalizing the run time of two loads. This alternating action is initiated by a control switch, such as a float switch, manual switch&, timing relay, pressure switch, or other isolated contact. Each time the initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay.

Cross-wired alternating relays are also used where additional capacity is required in case of excess load requirements. Not only will this version alternate between two loads, but it also allows both loads to run simultaneously when the lead and lag switches are closed, thus providing a way for both loads to operate when running just one does not provide enough capacity.

Duplex Alternating Relays are available in two output configurations: SPDT and DPDT cross-wired. See KnowledgeBase Article for more information.

Each version is available with an optional three position selector switch. This allows the unit to alternate the two loads as normal, or lock the relay to one load or the other. By locking the Alternating Relay to one load, the other load can be removed for service without rewiring the first load for continuous operation. In addition, on cross-wired versions, locking a load to always operate first allows the user to balance the run time of both loads if one load has fewer hours of operation than the other. The selector switch has a low profile to prevent any accidental changes in status

 

Macromatic's Alternating Relays Knowledge Base contains general and technical industry articles to help you learn more about Alternating Relays.

Flange-enclosure designed for deadfront door-mounting

Flange-enclosure designed for deadfront door-mounting

Top-Mounted Switch accessible without opening inner door

Top-Mounted Switch accessible without opening inner door

Sign Up For Macromatic's Newsletter

©2024 Macromatic Industrial Controls, Inc.

2201 Corporate Drive
Waukesha, WI 53189

800-238-7474 • 262-781-3366

Rep Login | Newsletter Sign Up | Articles | Employment | Privacy Policy | Sitemap
Knowledgebase General | Alternating Relays | Current Sensing Relays | Intrinsically Safe Barrier Relays | Liquid Level Control Relays | Seal Leak Relays | Three-Phase Monitor Relays | Time Delay Relays | Voltage Monitor Relays